Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Sci Total Environ ; 838(Pt 1): 155884, 2022 Sep 10.
Article in English | MEDLINE | ID: covidwho-2328273

ABSTRACT

Public health departments such as CDC and California Department of Public Health (CA-DPH) advise HEPA-purifiers to limit transmission of SARS-CoV-2 indoor spaces. CA-DPH recommends air exchanges per hour (ACH) of 4-6 air for rooms with marginal ventilation and 6-12 in classrooms often necessitating multiple HEPA-purifiers per room, unaffordable in under-resourced community settings. Pressure to seek cheap, rapid air filtration resulted in proliferation of lower-cost, Do-It-Yourself (DIY) air purifiers whose performance is not well characterized compared to HEPA-purifiers. Primary metrics are clean air delivery rate (CADR), noise generated (dBA), and affordability ($$). CADR measurement often requires hard-to-replicate laboratory experiments with generated aerosols. We use simplified, low-cost measurement tools of ambient aerosols enabling scalable evaluation of aerosol filtration efficiencies (0.3 to 10 µm), estimated CADR, and noise generation to compare 3 HEPA-purifiers and 9 DIY purifier designs. DIY purifiers consist of one or two box fans coupled to single MERV 13-16 filters (1″-5″ thick) or quad filters in a cube. Accounting for reduced filtration efficiency of MERV 13-16 filters (versus HEPA) at the most penetrating particle size of 0.3 µm, estimated CADR of DIY purifiers using 2″ (67%), 4″ (66%), and 5″ (85%) filters at lowest fan speed was 293 cfm ($35), 322 cfm ($58), and 405 cfm ($120) comparable to best-in-class, low-noise generating HEPA-purifier running at maximum speed with at 282 cfm ($549). Quad filter designs, popularly known Corsi-Rosenthal boxes, achieved gains in estimated CADR below 80% over single filter designs, less than the 100% gain by adding a second DIY purifier. Replacing one of the four filters with a second fan resulted in gains of 125%-150% in estimated CADR. Tested DIY alternatives using lower-efficiency, single filters compare favorably to tested HEPA-purifiers in estimated CADR, noise generated at five to ten times lower cost, enabling cheap, rapid aerosol removal indoors.


Subject(s)
Air Filters , Air Pollution, Indoor , COVID-19 , Aerosols , Air Pollution, Indoor/analysis , Air Pollution, Indoor/prevention & control , COVID-19/prevention & control , Dust , Humans , Pandemics/prevention & control , SARS-CoV-2
2.
Chinese Science Bulletin-Chinese ; 67(16):1783-1795, 2022.
Article in English | Web of Science | ID: covidwho-2307753

ABSTRACT

In response to the construction process of Healthy China. it is rather important to create a safe, healthy and energy-efficient indoor environment for public buildings. The public building space is often densely populated, with a large flow of people and many types of air pollution, which presents non-uniform dynamic distribution characteristics. This brings great challenges to the control of indoor air safety, especially during the pandemic period of COVID-19. Excessive ventilation may not only cause large energy waste. but also lead to cross-contamination and even a cluster of infection. In this paper, an operation and maintenance (O&M) control system for indoor air safety is developed based on the core concepts and basic methods of human ergonomics. In this system, one of the important human environmental variables is focused for control, i.e.. indoor air pollution level. Especially after the outbreak of COVID-19. droplets and droplet nuclei from respiration are the most significant air pollution categories required for mitigation. Towards the efficient control of air pollution in large public buildings. it should further take into account the interaction of human, equipment and machines (i.e., ventilation_ air purification and disinfection and intelligent control system) and building environment. Firstly, on the basis of the online monitoring of indoor air pollution concentration and personnel flow, the non-uniform dynamic distribution of indoor pollutants and personnel can be obtained by using the non-uniform and low-dimensional rapid prediction models and computer vision processing. Then, the optimal setting results of ventilation parameters (e.g., ventilation modes, supply air rate. etc.) can be outputted by the environmental control decision system. Finally, based on a combination of monitoring sensors, controllers and actuator hardware equipment (at the location of fans or dampers), the intelligent regulation and control of ventilation system can be realized, aimed at minimizing energy consumption and reducing pollutant concentration and exposure level. Meanwhile, the air purification and disinfection system (especially for the disinfection of virus particles) are operated under the condition of the ventilated environment, which can serve as a powerful auxiliary to the maintenance of indoor air safety. The workflow and effect of the O&M control system are demonstrated by an engineering application case of the front hall in the International Convention and Exhibition Center. The results indicate that the non-uniform and low-dimensional rapid prediction model for pollutant concentration is effective for the ventilation control with the average prediction difference of 11.9%. The implementation of the intelligent ventilation system can reduce the risk of human infection to less than 4%. and its energy-saving ratio for the ventilation can be as high as about 45%. Through optimizing the layout strategies of disinfection devices based on the intelligent ventilation control, the space accessibility of negative oxygen ions can be well accepted, to further increase the removal efficiency of air pollution. The calculated value of space disinfection rate is more than 99%, which can further reduce the risk of infection by 1-2 orders of magnitude. This study can provide an important reference for the promotion and upgrading of O&M control system for indoor air safety.

3.
Arh Hig Rada Toksikol ; 73(4): 270-276, 2022 Dec 01.
Article in English | MEDLINE | ID: covidwho-2310408

ABSTRACT

Even though ozone has shown its potential for air disinfection in hospital environment, its more frequent use has earned attention only with the COVID-19 pandemic due to its proven antimicrobial effect and low cost of production. The aim of this study was to determine its antimicrobial efficiency against the most common bacterial species in a real-life setting, that is, in the air of one postoperative room of the General Hospital Dr Ivo Pedisic (Sisak, Croatia). Air was sampled for aiborne bacteria before and after treatment with the ozone concentration of 15.71 mg/m3 for one hour. The most dominant Gram-positive bacteria of the genera Micrococcus, Staphylococcus, and Bacillus were reduced by 33 %, 58 %, and 61 %, respectively. The genus Micrococcus proved to be the most resistant. Considering our findings, we recommend longer air treatment with higher ozone concentrations in combination with mechanical cleaning and frequent ventilation.


Subject(s)
COVID-19 , Ozone , Humans , Disinfection , Pandemics , Air Microbiology , COVID-19/prevention & control , Bacteria , Hospitals
4.
Chinese Science Bulletin-Chinese ; 67(16):1783-1795, 2022.
Article in Chinese | Web of Science | ID: covidwho-1928264

ABSTRACT

In response to the construction process of Healthy China. it is rather important to create a safe, healthy and energy-efficient indoor environment for public buildings. The public building space is often densely populated, with a large flow of people and many types of air pollution, which presents non-uniform dynamic distribution characteristics. This brings great challenges to the control of indoor air safety, especially during the pandemic period of COVID-19. Excessive ventilation may not only cause large energy waste. but also lead to cross-contamination and even a cluster of infection. In this paper, an operation and maintenance (O&M) control system for indoor air safety is developed based on the core concepts and basic methods of human ergonomics. In this system, one of the important human environmental variables is focused for control, i.e.. indoor air pollution level. Especially after the outbreak of COVID-19. droplets and droplet nuclei from respiration are the most significant air pollution categories required for mitigation. Towards the efficient control of air pollution in large public buildings. it should further take into account the interaction of human, equipment and machines (i.e., ventilation_ air purification and disinfection and intelligent control system) and building environment. Firstly, on the basis of the online monitoring of indoor air pollution concentration and personnel flow, the non-uniform dynamic distribution of indoor pollutants and personnel can be obtained by using the non-uniform and low-dimensional rapid prediction models and computer vision processing. Then, the optimal setting results of ventilation parameters (e.g., ventilation modes, supply air rate. etc.) can be outputted by the environmental control decision system. Finally, based on a combination of monitoring sensors, controllers and actuator hardware equipment (at the location of fans or dampers), the intelligent regulation and control of ventilation system can be realized, aimed at minimizing energy consumption and reducing pollutant concentration and exposure level. Meanwhile, the air purification and disinfection system (especially for the disinfection of virus particles) are operated under the condition of the ventilated environment, which can serve as a powerful auxiliary to the maintenance of indoor air safety. The workflow and effect of the O&M control system are demonstrated by an engineering application case of the front hall in the International Convention and Exhibition Center. The results indicate that the non-uniform and low-dimensional rapid prediction model for pollutant concentration is effective for the ventilation control with the average prediction difference of 11.9%. The implementation of the intelligent ventilation system can reduce the risk of human infection to less than 4%. and its energy-saving ratio for the ventilation can be as high as about 45%. Through optimizing the layout strategies of disinfection devices based on the intelligent ventilation control, the space accessibility of negative oxygen ions can be well accepted, to further increase the removal efficiency of air pollution. The calculated value of space disinfection rate is more than 99%, which can further reduce the risk of infection by 1-2 orders of magnitude. This study can provide an important reference for the promotion and upgrading of O&M control system for indoor air safety.

5.
Journal of Building Engineering ; 50:104157, 2022.
Article in English | ScienceDirect | ID: covidwho-1665209

ABSTRACT

The COVID-19 pandemic has led to increasing interest in controlling airborne virus transmission during the operation of air-conditioning systems. Therefore, beyond an examination of the ability of liquid-desiccant material itself to inactivate microbes, a heat-pump-driven liquid-desiccant air-conditioning system was proposed and constructed to experimentally investigate the effect of liquid-desiccant solution on the inactivation of airborne bacteria and fungi in various air-conditioning processes. The proposed system comprises a liquid-desiccant unit to dehumidify or humidify process air using a desiccant-solution and heat-pump unit to cool or heat it and accommodate solution thermal loads. The decrease in the concentration of airborne bacteria and fungi before and after passing through the system (i.e., inactivation efficiency) were compared for the base, summer, and winter operating modes. The results indicated that airborne fungi were less inactivated than bacteria because they possess more stress-resistant cellular structures that resist inactivation. During the air-conditioning processes in both the summer and winter operating modes, the bacterial and fungal inactivation efficiencies improved compared to the base mode owing to the contact with desiccant solution. The higher solution flow rate and solution temperature improved the bacterial inactivation efficiency by 27% for the winter compared to the summer mode. Conversely, because of possible growth of fungi in the heated and humidified supply air in the winter, the fungal inactivation efficiency improved by only 1.5% for the winter compared to the summer mode. In conclusion, the proposed system can contribute to control the airborne transmission of microbial contaminants while operating air-conditioning systems.

6.
Atmosphere ; 13(1):45, 2022.
Article in English | ProQuest Central | ID: covidwho-1635429

ABSTRACT

We characterized the composition, diversity, and potential bacterial aerosol sources in Athens’ urban air by DNA barcoding (analysis of 16S rRNA genes) during three seasons in 2019. Air samples were collected using the recently developed Rutgers Electrostatic Passive Sampler (REPS). It is the first field application of REPS to study bacterial aerosol diversity. REPS samplers captured a sufficient amount of biological material to demonstrate the diversity of airborne bacteria and their variability over time. Overall, in the air of Athens, we detected 793 operational taxonomic units (OTUs), which were fully classified into the six distinct taxonomic categories (Phylum, Class, Order, etc.). These OTUs belonged to Phyla Actinobacteria, Firmicutes, Proteobacteria, Bacteroidetes, Cyanobacteria, and Fusobacteria. We found a complex community of bacterial aerosols with several opportunistic or potential pathogens in Athens’ urban air. Referring to the available literature, we discuss the likely sources of observed airborne bacteria, including soil, plants, animals, and humans. Our results on bacterial diversity are comparable to earlier studies, even though the sampling sites are different or geographically distant. However, the exact functional and ecological role of bioaerosols and, even more importantly, their impact on public health and the ecosystem requires further air monitoring and analysis.

SELECTION OF CITATIONS
SEARCH DETAIL